Industrial Rectifiers have a special operating algorithm. Since it has a three-phase input, it has a quality DC output signal. There is a distribution panel suitable for the system. It produces perfect solutions for industrial facilities and energy production organizations with the Configurations listed below. Special designs are made according to your needs.
High Gauss sheets and H class copper wires are used in the input isolation transformer, and they are varnished and baked under vacuum.
It has a wide range of information and control capabilities. It is an excellent alternative to equivalent products supplied from abroad due to its quality, economy and ease of service.
Information about the operating status is given to the user via 0-10V and 4-20 mA analog signals, and it has a Modbus communication option.
Information about the operating status of the industrial rectifier can also be monitored on the TFT panel or LCD screen.
Depending on the place of use, cooling is provided with a panel type air conditioner. Our industrial rectifiers are completely dry type and do not contain rectifier oil.
General Features
➤ Input Isolation Transformer
➤ L-C Filter
➤ Microprocessor controlled
➤ Thyristor – thyristor Module Structure
➤ soft start opening
➤ 2X16 Line LCD
➤ EMI filter
➤ Cooling with air conditioning
➤ Interior lighting lamp
➤ Serial connection via board
➤ emergency stop button
➤ Dry Contact information
➤ In-panel spare AC socket
➤ fiberglass protection
➤ Panel: branded or unbranded panel options
➤ Ability to use as current source and voltage source
➤ 24V/48V/110V/220V/500VDC options
➤ Production in the range of 10A – 1,000ADC.
➤ 6 pulse or 12 pulse options
➤ Choice of automatic or manual charging modes
➤ Output voltage regulation with dropper diode
➤ Battery monitoring, battery low information and protection in case of mains failure
➤ Modbus communication
➤ Monitoring and control via RS232-RS485,
➤ Plinth height option to suit your needs
PROTECTIONS
➤ Overcurrent (electronic)
➤ Short circuit (electronic)
➤ Semiconductor Overheat
➤ Transformer overheat
➤ DC high (electronic)
➤ DC Low (electronic)
➤ Mains high (electronic)
➤ input fuse
➤ DC Output fuses
➤ DC Distribution fuses
➤ Emergency protection button
INDICATORS
➤ 2×16 Line LCD screen
➤ Input voltage, output voltage, output current, error information tracking
➤ Display language selection (English, Turkish)
➤ Output voltage Analog or Digital voltmeter
➤ Output current Analog or Digital ammeter
➤ LED status notification
REMOTE ACCESS
➤ ON-OFF Control
➤ Rectifier Start
➤ Output voltage adjustment with 0-10V control
➤ 0-10V control Output Current Adjustment
WARNING and OPERATING CONDITION INFORMATION
➤ DC High (Dry contact)
➤ DC Low (Dry contact)
➤ Mains High (dry contact)
➤ Excessive Heat (dry contact)
➤ Overcurrent (dry contact)
➤ Earth leakage (Dry contact)
➤ Output voltage information with analog signal (0 – 10V or 4-20 mA)
➤ Current information with analog signal (0 – 10V or 4-20 mA)
TERMINALS
➤ input terminals
➤ DC output terminals
➤ Remote control terminals
➤ Warning information